CONTROL
PANEL
TROUBLESHOOTING
MANUAL
STARTER
DISCONNECT
(TOGGLE
SWITCHES)
NOTE:
The
engine
control
system
is
protected
by
a 20
amp
manual reset circuit breaker
located on the engine
as
close as possible
to
the
power
source.
Problem
Probable
Cause
Verification/Remedy
PREHEAT
depressed,
no
panel
indications
1.
Oil
Pressure
switch.
1.
Check
switches
and/or
battery
connections.
fuel
solenoid,
electric
fuel
pump
and
preheat
solenoid
not
energized.
2.
20
amp
circuit
breaker
tripped.
2.
Reset
breaker.
If
it
opens
again,
check
preheat
solenoid
circuit
and
run
circuit
for
shorts
to
ground.
START
SWITCH
DEPRESSED,
no
starter
1.
Connection
to
solenoid
faulty.
1.
Check
connection.
engagement.
2.
Faulty
switch.
2.
Check
switch
with
ohmmeter.
3 ..
Faulty
solenoid.
3.
Check
that
12
yolts
are
present
at
the
solenoid
connection.
4.
Loose
battery
connections.
4.
Check
battery
connections.
5
Low
battery.
5.
Check
battery
charge
state.
NO
IGNITION,
cranks,
does
not
start.
·1.
Faulty
fueling
system.
1.
Check
for
fuel.
2.
Check
for
air
in
the
fuel
system.
2.
Allow
system
to
bleed.
3.
Faulty
fuel
lift
pump.
3.
Replace
fuel
lift
pump.
NOT
CHARGING
BATTERY
1.
Faulty
alternator
drive.
1.
Check
the
drive
belt
and
its
tension.
Be
sure
the
alternator
turns
freely.
Check
for
loose
connections.
Check
the
output
with
a
voltmeter.
Ensure
12V
are
present
at
the
regulator
terminal.
BATTERY
RUNS
DOWN
1.
Oil
pressure
switch.
1.
Observe
if
the
gauges
and
panel
lights
are
activated
when
the
engine
is
not
running.
Test
the
oil
pressure
switch.
2.
High
resistance
leak
to
ground.
2.
Check
the
wiring.
Insert
sensitive
(0-.25
amp)
meter
in
battery
lines
(Do
NOT
start
engine).
Remove
connections
and
replace
after
short
is
located.
3.
Low
resistance
leak
to
ground.
3.
Check
all
wires
for
temperature
rise
to
locate
the
fault.
4.
Faulty
alternator.
4.
After
a
good
battery
charging,
disconnect
alternator
at
output.
If
leakage
stops.
Remove
alternator
and
bench
test.
Repair
or
replace.
TROUBLESHOOTING
WATER
TEMPERATURE
AND
OIL
PRESSURE
GAUGES
If
the
gauge
reading
is
other than what
is
normally indicated
by
the
gauge
when
the
instrument panel
is
energized, the
first
step
is
to
check
for
12
volts DC between the ignition
(B+)
and
the Negative (B-) terminals of the gauge.
Assuming
that there
is
12
volts
as
required, leave the
instrument panel energized and
perfmm the following
steps:
1.
Disconnect the sender wire at
the
gauge and see
if
the
gauge
reads
zero, which
is
the nonnal reading for this
situation.
2.
Remove
the
wire
attached
to
the
sender terminal at
the
gauge
and
connect it
to
ground.
See
if the gauge reads
full
scale,
which
is
the nonnal reading for this situation.
38
If
both of the above
gauge
tests
are positive,
the
gauge
is
undoubtedly OK
and
the problem lies either
with
the
conductor from the sender
to
the
gauge
or
with
the
sender.
If
either of the above gauge tests
are
negative,
the
gauge
is
probably defective and
should
be
replaced.
·
Assuming the gauge
is
OK,
check
the
conductor
from
the
sender
to
the
sender terminal at
the
gauge
for
continuity.
Check
thqt
the
engine block
is
connected
to
the
ground.
Some
starters have isolated
ground
tenninals
and
if
the
battery
is
connected
to
the
starter
(both
plus
and
rninus
temlinals), the ground side
will
not necessarily
be
connected
to
the
block.