DC
Electrical
Connections
A
common
ground
for
the negative
(-)
DC terminal connection is found at the bell housing
of
the generator,
next
to
the starter, in the form
of
a threaded grounding stud. The battery ground should be connected at
this stud.
Connect the battery's positive (
+)
connection
to
the starter solenoid tagged
for
this connection.
CAUTION
To avoid an overcharging condition, and a possible equipment failure,
DO
NOT
disconnect
the DC battery source while the engine is running.
Automatic
Shutdown
High Exhaust Temperature Shutdown Switch (normally closed)
An exhaust temperature switch is located on the exhaust elbow. Should the switch's sensor indicate an ex-
cessive exhaust temperature, the switch will open and shut the generator
OFF (an inadequate supply of sea
water coolant causes high exhaust temperatures). This switch opens at 260 - 270
0
F (127 - 132
0
C)
and
resets at approximately
225
0
F
(1
O~
C).
High Water Temperature Shutdown Switch (normally closed)
A high water temperature switch is located on the thermostat housing. Should the fresh water coolant's
operating temperature reach approximately 205
0
F (96
0
C), the switch will open and shut the generator OFF.
This switch resets at 195
0
F
(10~
C).
Low
Oil
Pressure Shutdown Switch (normally open)
A
low
oil pressure shutdown switch is located off the engine's oil gallery. The switch's sensor monitors the
engine's oil pressure. Should the engine's oil pressure fall
to
10 - 15 psi, the switch will open and turn the
generator
OFF.
Generator
(AC
Output)
Make sure that the AC output connections within the generator's distribution
box
are tight and
in
accordance
with the specific AC Load Connections diagram found later in this manual. (See the "BC GENERATOR" sec-
tion
of
this manual, page 54.)
Do
not
smoke
or
allow an open flame near batteries. Lead acid batteries emit hydrogen, a
highly-explosive gas.