Westerbeke 38B FOUR Manual do Operador Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 108
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 38
Admirals
Panel
General
The manually-controlled Admirals Panel is equipped with a Key
Switch and an
RPM
gauge with an ELAPSED
TIME
meter which measures the engine's running time in HOURS and
in
1/10 hours. The panel also includes
a water temperature gauge which indicates water temperature in degrees Fahrenheit (WATER
0
F),
an oil
pressure gauge which measures the engine's oil pressure
in
pounds per square inch (OIL PSI), and a DC
control circuit voltage gauge which measures the system's voltage
(VOLTS).
All
gauges are illuminated when
the key switch is turned
ON and remain illuminated while the engine is in operation. The panel also contains
two rubber-booted push buttons, one for PREHEAT and one for
START.
1.
Key Switch: The Key Switch provides power only
to
the instrument cluster. Refer
to
the "STOPPING
PROCEDURE"
section
of
this manual, page 41.
2.
PREHEAT: The PREHEAT button activates the alternator's exciter, the engine's
glow
plugs, and bypas-
ses the engine's protective oil pressure switch.
In addition, this button is energizes the START button.
3.
SIABI:
The START button, when pressed, energizes the starter's solenoid which cranks the engine.
This button will
not
operate electrically unless the PREHEAT button is pressed and held at the same
time.